Flue & Ducting Ltd
DuraFlue 316 & 904
HETAS ID: | EC056 |
---|---|
App. Type: | Double Skin Flexible Chimney Relining Systems |
Std. Tested to: | BS EN 1856-2:2004 |
Flue Sizes: | 100*, 130*, 150*, 180*, 200*, 250, 300, 350, 400 mm round |
Performance
HETAS has audited and verified that all applicable clauses in the test report have been passed in respect of the materials, design, and construction in accordance with the relevant BS EN type test standard for the appropriate technology, performance criteria of which is below;
Temperature Level | T450 |
---|---|
Pressure Level | N1 |
Condensate Resistance | D |
Corrosion Resistance | V3 |
Flue Liner Material Specification | L50040 |
Sootfire Resistance (G:yes or O:no) and distance to combustible material (in mm) | G60 |
Safety
The product certified has been assessed for its suitability for installation in domestic properties against the requirements of the Building Regulations and appropriate standards. The performance of the appliance has been verified as meeting the following technical performance attributes;
CE Mark Certificate | > 0036-CPR 91385 002 |
---|
*HETAS product approval is not valid for appliances fitted with an external air supply ducted directly to the appliance. The installer should reference HETAS technical note TN_0020 General Guidance for the Installation, Risk Assessment & Commissioning of Solid Fuel Appliances with a Dedicated External Air Supply for more information.